Float charging voltage
1KW default setting: 13.5V
2KW default setting: 27.0V
3KW default setting: 54.0V
This is selectable when item 05 is set to USER-DEFINED
- Selection range (1KW model): 12.0V to 16.0V
- Selection range (2KW model): 24.0V to 32.0V
- Selection range (3KW model): 48.0V to 64.0V
Increments of 0.1V per click
28
AC output mode
*This setting is accessible
only when the inverter is in
standby mode (switched
off)
Single:
When the units are used in parallel
on a single-phase system, select
PAL
in item 28.
It requires a minimum of 3 or a
maximum of 9 inverters to support
the three-phase mode. At least
one inverter is needed in each
phase or up to four inverters in one
phase.
Refer to the
Parallel
operation
section for detailed information.
Parallel:
L1 phase:
Select
3P1
in item 28 for the
inverters connected to the L1
phase,
3P2
for the inverters
connected to the L2 phase, and
3P3
for the inverters connected to
the L3 phase.
The share current cable must be
connected to all units which are on
the same phase.
Do NOT connect the share current
cable between units on different
phases.
L2 phase:
L3 phase: