19
16
Charger source priority:
This item controls which
source is used first to
charge the batteries and
power the loads
SbL: Solar for battery first
UCB: Utility power available to
charge battery (default)
Solar energy will be used to charge
the battery as first priority.
AC power can be used to charge
the battery when solar energy is not
available
SbL: Solar for battery first
UdC: Utility power not allowed
to charge battery
Solar energy will be the only charger
source regardless of whether the AC
is available or not
SLb: Solar for load first
UCb: Utility power available to
charge battery
Solar energy will provide power to the
loads first. AC power will be used to
charge the battery when solar energy
is not available
SLb: Solar energy for load first
UdC: Utility power not allowed
to charge battery
Solar energy will be the only charger
source nregardless of the AC source
availability
18
Alarm control
Alarm on (default)
Alarm off
19
Auto-return to default
display screen
Auto-return screen (default)
Sets the screen to return to the
default display (Input voltage /output
voltage) after 1 minute if no button is
pressed
Stay on current screen
If selected, the display will remain
unchanged
20
Backlight control
Backlight on (default)
Backlight off
22
Beeps when the primary
source is interrupted
Alarm on (default)
Alarm off
Summary of Contents for Fusion FIO-F11K12P