52
Table 3
Charge mode specifications
Utility charging mode
INVERTER MODEL
1KW
2KW
3KW
Charging current
at Nominal input voltage
Default: 30A, max: 60A
Bulk charging
voltage
Flooded battery
14.6VDC
29.2VDC
58.4VDC
AGM / Gel
battery
14.1VDC
28.2VDC
56.4VDC
Floating charging voltage
13.5VDC
27VDC
54VDC
Overcharge protection
16.5VDC
33VDC
66VDC
Charging algorithm
3-step with equalization
Charging curve
Solar charging mode (MPPT type)
INVERTER MODEL
1KW
2KW
3KW
Rated power
1000W
2000W
4000W
Maximum charging current
80A
Solar charging efficiency
82.0% max.
89.0% max.
94.0% max.
Max. PV array open circuit voltage
145VDC
PV array MPPT voltage range
15~115VDC
30~115VDC
60~115VDC
Battery voltage accuracy
+/-0.3%
PV voltage accuracy
+/-5V
Charging algorithm
3-step with equalization
Utility and solar charging
Max charging current
140A
Default charging current
60A
Summary of Contents for Fusion FIO-F11K12P