- 797 -
Metric Value
- Set the metric value you want applied for the default route advertised into the area.
Valid values range from 1 to 16,777,215.
Import Summary LSAs
- Whether the import of Summary LSAs is enabled or disabled.
Command Buttons
Refresh
- Refresh the data on the screen to the current values from the switch.
11.4.3.4 Configuring Area Range
Selection Criteria
Area ID
- Selects the area for which data is to be configured.
Configurable Data
IP address
- Enter the IP Address for the address range for the selected area.
Subnet Mask
- Enter the Subnet Mask for the address range for the selected area.
LSDB Type
- Select the type of Link Advertisement associated with the specified area and address
range. The default type is 'Network Summary'.
Advertisement
- Select enable or disable from the pulldown menu. If you selected enable the
address range will be advertised outside the area via a Network Summary LSA. The default is
enable.
Non-Configurable Data
Area ID
- The OSPF area.
IP address
- The IP Address of an address range for the area.
Subnet Mask
- The Subnet Mask of an address range for the area.
LSDB Type
- The Link Advertisement type for the address range and area.
Advertisement
- The Advertisement mode for the address range and area.
Command Buttons
Create
- Send the updated configuration to the switch. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is performed.
The new address range will be added to the display in the non-configurable data area.
Delete