FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
Figure 3.4
4.1
On the screen you can see the current setting parameters. They have the following
meaning:
Detector:
Information about detectors model
FMC,
operation frequency
24
(24.525
GHz), operation length.
Version:
Version of software
Alarm type:
Relay (normal close contact)
Unit ID:
It means the frequency modulation of the receiver. The transmitter and
receiver should be on the same frequency modulation (1A ~ 4B). Frequency modulation
changing using the switches (see 2.4.)
Zone length:
The currently selected operation distance for the detector. It is really
important to choose the proper operation distance.
Note: It is used only in Setup Method: AUTO
Note: If the zone length is not the real distance, there might be higher false alarm
rate or poor sensitivity.
Setup method:
The currently selected setup method. You can choose “Auto, ‘Manual’,
SPECIAL 1 or SPECIAL 2 setup modes. In ‘Manual’ setup you can set sensitivity, in ‘Auto’
setup you can change ‘Zone length’.
In most of the cases ‘Auto’ setting is recommended.
Sensitivity:
It means the sensitivity of detection. You can only set sensitivity in
‘Manual’ Setup method. In most of the cases sensitivity setting is not recommended.
Speed:
It is the motion speed range which is identified by the detector.