FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
horizontally for more exact adjustment. After finishing adjustment work, check the signal
value. The boundary values of 50 mV and 800 mV during the adjustment are recommended
.
NOTE: There should be at least 50 mV minimum signals. Detectors installation
height is 95 cm. If you cannot reach it: change the position (95 cm + 5 cm or 95 cm – 5
cm.) of the detectors or the operating distance;
5.6.
If the voltage controlled by the calibration is over 800 mV (on short sectors), it is
recommended to make the desalignment of Rx and Tx upwards at a small angle so the
voltage does not exceed 800 mV.
NOTE: Don’t desalting Rx and Tx down or towards.
5.7.
Don’t desalting Rx and Tx down or towards. The detector keeps its operation
using “Calibration” voltage …2.5 mV. The recommended boundary values of 8 mV and 200
mV during the adjustment are recommended for the resource of the signal level to provide a
long operation.
6.
SETTING THE THRESHOLD (LIMIT VALUES) USING ANDROID
6.2
After successful calibration you can come back to setup menu. Here you can
define the working parameters of the detectors. Signal must be stable, within the range +15
mV or -15 mV, if the noises signal is changing more than +15 mV or -15mV please check
the detection zone, there can be moving objects. If you can’t remove them or there is no
moving object which can make influence to detection zone, please use manual setup method.
Were set up the sensitivity level 2-3 times higher than existing noises signal level. Follow
2.5.5.4. if detector don’t generate the alarms throw passages, clear the detection zone us
write in 2.1.3