FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
Note: Too big speed range has higher false alarm rate, too low speed range has poor
sensitivity.
Signal:
Shows the signal between transmitter and receiver.
Save
alarms:
It is a useful function if the installer is alone. With this function you can
count alarms, so you can check your detector with test crossings. With ‘Reset’ button you
can reset the counter.
5.
SENSOR ADJUSTMENT WITH ANDROID DEVICE
5.1.
Perform a preliminary adjustment of Tx and Rx with a sight leaf (i. 2.4.1).
5.2.
Before any changes in Setup bookmark, you need to calibrate your detector. You
can make it if you select Calibration bookmark.
5.3.
Firstly you need to calibrate (fine positioning) the transmitter unit, then the
receiver unit.
Fig.2.13
5.4.
Here you can see the received signal from the transmitter on a dynamically
changing scale. The maximum value of the current positioning is always signed. If you are
close to the maximum value of the current positioning, the changing lane becomes green. It
means the positioning made well. If the lane is red, you should continue positioning as you
are not close to the maximum value. With ‘Reset maximum’ button you can reset the current
maximum, and you can look for another reference value.
Note: Always recommended a few minutes of positioning to have a good maximum
value of current positioning, what you can use as a reference.
5.5.
Check the value of “Calibration” voltage as a result of the adjustment. If
“Calibration” voltage is less than 3 mV, it is necessary to repeat the alignment vertically and