FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
Transmitters control panel ( TX )
Fig. 1.5
Markings (TX):
1 – LED indication
2 – Tamper circuit
3 – Frequency band switch 1-8
Note. Dear user! The manufacturer of the detector constantly upgrades their quality and
reliability. That’s why in some lots of detectors one can find design modifications
unspecified in the documents delivered with the detectors. Nevertheless, the main
specifications are valid.
1.6. Adjustment, control and indication parts
1.6.1. The micro channels switches provided the frequency channels switch are set on
the transmitter and the receiver. Only one of four switches can be set with the same number
on the receiving and the transmitting side when the power supply is ON.
1.6.2. Adjustment and control of the sensors is performed by using the controller
placed on the receivers panel, using Android or Windows software.
1.6.3. Manual adjustment: adjustment is possible without software, only visually
"from the eye".
1.6.4. Possibilities when using Android or Windows device: visualization of
calibration; selection of the detection zone length; AUTOMATIC, MANUAL or SPECIAL
sensitivity adjustment modes.
1.6.5. To prevent unauthorized openings of the cover 6 (fig.1.2), a tamper button is
placed in the receiver. The tamper contacts are closed in the operating state. When the cover