2.4.2.5. Positioning (calibration) is done gradually. Calibration can only be started
when the transmitter LED is solid green and the receivers LED is solid green or flashing
red. If the LED on the receiver will light in red continuously - calibration is not possible.
Positioning work can be started from both the transmitter and the receiver. In manual
mode calibration is performed visually (from the eye).
2.4.3 Sensitivity adjustment
2.4.3.2. Set the sensitivity parameters according to the tactics of crossing the guard
sections (standing or bending) over the entire length of the zone. It is recommended to
start such control crossings in the middle of the protected area.
After each pass, you must
walk outside the detection zone at a distance of 2-4 m and wait for about 5-7 seconds
.
Otherwise, the results obtained in the previous pass may affect the results of the next pass.
2.4.3.4. Perform test runs in problematic areas of the detection zone: trenches, hills,
spaces near barriers, buildings and trees, which are in the detection zone. If necessary,
change the sensitivity of the sensor.
Note. If, at the factory settings, the sensor does not activate an alarm during the test
run, please adjust the sensitivity using the “Forteza soft” program.
2.4.3.5. When adjustment work is finished, close the covers of the receiver and
transmitter terminals.
Leave the “BT” and “RS-485” switches in off state (if not used for remote setting).
2.4.3.6. After completing the sensor adjustment work, after 2-3 days we recommend
performing a system startup test in order to detect and eliminate any installation and
adjustment errors.
2.5. Software installation and detector adjustment by ANDROID device (using built-
in Bluetooth/RS-485 converter)
The android device allows checking the signal level, change sensitivity parameters,
detection zone length, giving a signal, setting some parameters inaccessible for Preliminary
adjustment.
3.
PRELIMINARY CONFIGURATIONS
Before using the package it is necessary to download and install Forteza Android
Software application at chosen Android–device.
When starting the application Connection Wizard connection configuration window
(Figure 3.1) appears.