FORTEZA JSC FORTEZA FMC 24 Pro (100m, 200m, 300m)
Please visit our internet sites:
-
Rx
111 mA
Individual point relay parameters:
Switching voltage
30 V maximum
Switching current
0,1 A maximum
Alarm contact resistance
100 Ohms maximum
“dead” zones
2…4 m
Readiness time
switch ON
30 sec maximum
switch OFF
1 sec maximum
The parameters of TAMPER button:
-
voltage
30 V maximum
-
current consumption
0,1 A maximum
Protection class
IP55
The configuration and the dimensions of the detection zone are given in fig.1.1. and
table 1.1
Table 1.1
Length of a sector,
L
, m
25
50
100
200
300
Detection zone width,
b
, m, max
0,7
1,0
1,5
1,9
2,1
Detection zone height,
h
, m,
max
1,4
1,4
1,6
1,8
1,8
1.2.2. The detection zone is a volumetric part of a sector that being the very specialty
in the kind of detection, and any movement within this sector will generate an alarm.
Fig.1.1. Detection zone