5.13 Roof
5.13.1 Roof Ventilation
E176161
1
Description
Item
Local form in Roof Panel
1
General -
Apertures must not cut through roof
bows, see figure E176161. Ventilators must prevent
direct entry of water and dust. A shut-off system
should be available to prevent fume ingress.
Interior and exterior projection legal requirements
must be maintained.
Ventilation Units -
The roof panel can support
up to 1kg on an unsupported area of roof. Loads
up to a maximum of 25kg must be distributed over
the full length of the roof rails between the roof
bows.
Air Conditioning Units -
Units weighing more
than 25kg must be internally supported on cross
brace members distributing the load out to the
roof rails.
5.13.2 Roof Cut Out - Camper Based Vehicles Only
E176162
1
2
3
A
B
Description
Item
Rivet and self tapping screw area
1
Bolting area
2
Bolting area providing bolts are between blue spot welds
3
Maximum roof cut out standard (Transit Motorhome Chassis with roof and back panel removed
Shown, for Camper Single Chassis Cab, the same fixing strategy applies).
A, B
Date of Publication: 03/2018
FORD
TRANSIT
2016.75
5 Body and P
aint
277
EU