![Ford NEW GENERATION STAR TESTER Introduction Manual Download Page 48](http://html1.mh-extra.com/html/ford/new-generation-star-tester/new-generation-star-tester_introduction-manual_2318799048.webp)
3-16
NGS-Navigation
LESSON 3
NOTES
SAMPLE RATE CHART
The table below shows a data chart that demonstrates the
sampling rate of the NGS unit when viewing and recording
PlDs.
NOTE: This information applies only to Ford’s diagnostic
communication link (DCL).
Some Ford PCMs offer over 100 PlDs of information. As
illustrated, the number of PlDs selected directly affects the
sampling rate or speed at which the NGS can operate. To use
the unit most efficiently, select as few PlDs as necessary,
allowing the fastest possible processing and display of
information.
Number of PIDs
selected:
One through four
One sampling of
all selected PIDs
every 0.1 seconds
(10 x per second)
Number of PIDs
selected:
Five through eight
One sampling of
all selected PIDs
every 0.2 seconds
(5 x per second)
Number of PIDs
selected:
Nine through
sixteen
One sampling of
all selected PIDs
every 0.4 seconds
(2.5 x per second)
Number of PIDs
selected:
Seventeen through
thirty-two
One sampling of
all selected PIDs
every 0.8 seconds
(1.25 x per
second)
Number of PIDs
selected:
Thirty-three
through sixty-four
One sampling of
all selected PIDs
every 1.6 seconds
(.625 times per
second)