138
Video Trigger
The Video Trigger setting dialog box for detailed settings opens.
After completing the settings, click
Close
to close the dialog box.
Click
Refresh
to update the settings.
SDI Error Trigger
Parameter
Default
Setting range
Description
Trigger Set
Disable
Disable
Enable
Enables or disables auto changeover
for SDI signal loss, an unsupported
video format, or TRS error.
Duration Immediate
Immediate
0.5 to 5.0 sec.
Sets the duration of SDI signal loss,
unsupported video format or TRS
error detection (in the active picture
area) required to trigger a
changeover.
Format Error Trigger
Parameter
Default
Setting range
Description
Trigger Set
Disable
Disable
Enable
Enables or disables auto changeover
for SDI input and system format
mismatches.
*1
Duration Immediate
Immediate
0.5 to 5.0 sec.
Sets the duration of the detected
format mismatch required to trigger a
changeover.
* Trigger Set cannot be enabled if System Format is set to Auto Detect. To enable the trigger,
set System Format to a video format other than Auto Detect in section 9-4-1 “FS Mode”.
* A changeover will not be performed if Changeover is disabled or Video Trigger is disabled
even though Format Error Trigger is enabled.
* Format Error Trigger also triggers a changeover for SDI input signal loss. If Format Error
Trigger is enabled and the SDI signal input is lost, a changeover will be performed, even
though SDI Error Trigger is disabled, based on the Format Error Trigger Duration setting.