79
Output
Level 1
Level 2
None
-
Unit Alarm
FAN 1/2/3/4 Alarm
(A FAN is in alarm state.)
FAN 1-4 Alarm
(The selected FAN is in alarm state.)
DC Power 1/2
*1
(A DC power is in alarm state.)
DC Power 1-2
*1
(The selected DC power is in alarm state.)
Alarm
(An alarm has occurred.)
Video In
FS 1-10 Video In
(An video signal is present in the selected FS.)
Reference In
(A reference signal is present in the selected FS.)
Audio In
FS 1-10 Audio In
(An audio signal is present in the selected FS.)
Option A-D Audio In
*2
(Audio signals are present in the selected option slot.)
Other
Input Function
(
*3
)
*1
DC Power 2 is displayed if the FA-10PS is installed.
*2
Option A-D Audio In are displayed if FA-10AES-BL/UBL/UBLC and/or FA-10ANA-AUD are installed in
respective slots A-D.
*3
The output function varies depending on the Input setting of the port. Refer to the
“Input Function
Operation Characteristics of GPI Output
” for details.
Invert
Allows you to select the output logic for Unit Alarm selected under Level 1.
NORM (Normal):
In an Alarm state, output is L (low).
INV (Invert): In an Alarm state, output is H (high).
Input Function Operation Characteristics of GPI Output
Input setting
Output Behavior (under Input Function)
All Freeze Frame
Outputs when Freeze Mode is set to Frame for all FSs 1-10.
All Freeze Odd
Outputs when Freeze Mode is set to Odd for all FSs 1-10.
All Freeze Even
Outputs when Freeze Mode is set to Even for all FSs 1-10.
FS 1-10 Freeze On/Off Outputs when Freeze is set to On for the subject FS.
All Freeze On/Off
Outputs when Freeze is set to On for all FSs 1-10.
SDI 1-10 By-pass On/Off Outputs when By-pass is set to On for the subject FS.
All By-pass On/Off
Outputs when By-pass is set to On for all FSs 1-10.
Time Code Start
Outputs when Time Code Starts.
Time Code Stop
Outputs when Time Code Stops.
Time Code Reset
No action.
Time Code Preset
No action.
Direct Mode
Outputs when Clean Switch is set to Direct Mode.
Take Mode
Outputs when Clean Switch is set to Take Mode.
Take
Outputs and does not output alternately when a Source is selected
for a Destination in Take Mode so that Clean Switch is in the Take
stand-by state.
Destination 1-10
Outputs when the subject Destination is selected.
Source 1-10
Outputs when the subject Source is selected.
Salvo 1-100
No action.
Event Load Default
Outputs and does not output alternately for about 3 seconds when
an Event Load is performed.
Event 1-100
Outputs and does not output alternately for about 3 seconds when
an Event Load is performed.
Video Test Signal
FS1-10 Off
Outputs when Video Test Signal is set to Off for the subject FS.
Video Test Signal
FS1-10 100% Color Bar
Outputs when Video Test Signal is set to 100% Color Bar for the
subject FS.