49
4-2-13. By-pass
The By-pass page allows you to set bypass outputs.
Input signals will be output to output connectors without being internally processed.
Item
Default
Setting
range
Description
All Input-All Output
Operate
Operate
By-pass
Allows you to set all inputs and outputs
simultaneously regardless of other
settings.
Operate
: Processes input signals.
By-pass
: By-passes input signals.
e.g. Input 1
→ Output 1, Input 10
→ Output
10
SDI X Input
→
SDI X Output Operate
Operate
By-pass
Allows you to set the By-pass setting for
each input connector.
Operate
: Processes input signals.
By-pass
: By-passes input signals.
(X: connector number)
By-pass cannot be set depending on FS
Input and FS Output settings. See the
“Important” note below.
* The front panel status LED for the by-passed input connector lights green.
IMPORTANT
SDI input assigned to multiple FSs in the FS Input menu (see sec. 4-2-1) or to an FS
assigned to multiple output connectors in the FS Output menu (see sec 4-2-12) cannot
be set to By-pass. e.g., FS 1 and 2 assigned to SDI 1, FS 5 assigned to SDI 1, 2, 3,
etc.
However, All Input-All Output bypasses all input signals from the input connector to the
same (numbered) output connector.