Operation Manual EMGZ 309.EIP
20.12.2018
27
kN
lb
g
kg
System Force
LCD:
SysForce
Use:
The System Force [
SysForce
] determines the measuring capability of
your measuring roller. E.g. If two 500 N sensors are installed in your
measuring roller, enter 1000N. If only one 500N sensor is used, enter
500N. If sensors with sheaves are used (e.g. RMGZ-Series), the
nominal force value (in our example 500 N) must be entered.
If the Device Mode [VoltGauge] is set, this parameter is deactivated
Unit
Parameter Range
Selection
Default
Min
Max
N, kN, g,
kg, lb
1)
1 100’000
-
1000
257)
The display shows the unit of measure that was
previously selected
Force at max. Amplifier Output
LCD:
F@OutMax
Use:
This parameter defines what force value (N, kN, lb, g, kg) corresponds
to the maximum output of the amplifier (10V or 20mA).
If the Device Mode [VoltGauge] is set, this parameter is deactivated
Unit
Parameter Range
Selection
Default
Min
Max
N, kN, g,
kg, lb
1)
1 100’000
-
1000
258)
The display shows the unit of measure that was
previously selected