Caution
Proper function of the Tension Measuring Amplifier is only guaranteed with the
recommended application of the components. In case of other arrangement, heavy
malfunction can be the result. Therefore, the installation instructions on the
following pages must be followed strictly.
Caution
Local installation regulations are to preserve safety of electric equipment. They are
not taken into consideration by this operating manual. However, they have to be
followed strictly.
3.4
Mounting the Force Sensors
Mounting of the force sensors is done according to the FMS Installation manual
which is delivered together with the force sensors.
3.5
W
iring the Amplifier
One or two force sensors can be connected to the measuring amplifier. When
using two force sensors, the sensors are internally connected in parallel. The
output signal of the measuring amplifier will then correspond to the average value
of the two sensors. The connection between force sensors and measuring
amplifier has to be done using a 2x2x0.25mm
2
[AWG 23] shielded twisted-pair
cable