Operation Manual EMGZ 309.EIP
20.12.2018
29
Offset Value
LCD:
Offset
Use:
The value determined with the adjustment procedure
Offset
Compensation
is stored as a Digit value in the parameter
Offset
. The
offset value is used to compensate the roller weight (see 4.4 “Offset
Compensation”).
Unit
Parameter Range
Selection
Default
Min
Max
Digit -8000 +8000
-
0
Gain of Amplifier
LCD:
Gain
Use:
This parameter stores the value determined with the Procedure
Calibration
(see 4.7 “Calibration over the Operating Panel”).
Alternatively you can input a calculated value using the FMS
Calculator described in chapter 4.8, if the material tension cannot be
simulated.
Unit
Parameter Range
Selection
Default
Min
Max
- 0.100 20.000
-
1.0
Device Mode
LCD:
DevicMod
Use:
The Device Mode determines the functionality of the amplifier. If
[VoltGaug] is set, force values will be displayed only in Volt (V) or
mA. Force units won’t be available.
Each change of the Device Mode requires a re-calibration of the system
(see chapter 4.8).
Unit
Parameter Range
Selection
Default
Min
Max
- - -
ForcGaug
VoltGaug
ForcGaug