Operation Manual EMGZ 309.EIP
20.12.2018
25
8
Parametrization via the operating panel
8.1
Reset to Default Parameter Set
Factory settings of your EMGZ309 amplifier can be re-set either over the
parameter setting menu (see 8.3 “Description of Parameters”) or as shown below:
Fig. 20: Reset to Default Parameter Set
E309018e
8.2
Parameter List
Parameter
Unit
Min
Max
Default
Remarks
Dis Filt.
[Hz]
0.1
10.0
1.0
Out Filt.
[Hz]
0.1
200.0
10.0
Unit
4)
[-]
N, kN, lb, g, kg.
N
SysForce
4)
[N]
1)
1 100’000
1000
F@OutMax
4)
[N]
1)
1 100’000
1000
Curr.Out
mA
0…20 or 4…20
4…20
Offset
[Digit]
–8000
8000
0
Gain
[-]
0.100 20.000 1.000
DevicMod
[-]
ForcGaug or VoltGaug
ForcGaug Each parameter
change requires
re-calibration
Language
[-]
English or German
English
Contrast [%] 1 100 65
Ethernet
[-]
On or Off
On
If
Off,
reduces
power
consumpt
IP Addr.
[-]
0
255
192
168
0
090
Address to be
entered in 4
blocks