Operation Manual EMGZ 309.EIP
20.12.2018
26
Subnet [-] 0 255
255
255
255
0
Address to be
entered in 4
blocks
Default [-]
No,
Yes
Yes
1)
The display shows the unit of measure that was previously selected.
4)
If the Device Mode [VoltGauge] is set, these parameters are deactivated
8.3
Description of Parameters
Display Filter
LCD:
Dis.Filt
Use:
The display filter (lowpass) steadies the value shown in the display
when there is a high fluctuation of the force values. The parameter
Dis.Filt
stores the cut off frequency of the filter. The lower the cut
off frequency, the more sluggish the display will be. The display
filter does not influence the output signal filter described in the
parameter
Out.
Filt
(see below).
Unit
Parameter Range
Selection
Default
Min
Max
Hz 0.1
10.0
-
1.0
Filter Amplifier Output
LCD:
Out.Filt
Use:
The EMGZ309 contains a lowpass filter to prevent noise overlaying
to the output signal. This parameter stores the cut off frequency of
the filter. The lower the cut off frequency, the more sluggish the
output signal will be. The filter stabilizes the output signal in case of
highly fluctuating force values. This filter is independent from the
display filter (see above).
Unit
Parameter Range
Selection
Default
Min
Max
Hz 0.1 200.0
-
10.0
Unit of Measure
LCD:
Unit
Use:
This parameter determines the unit system used
.
Note:
By changing the units to lb (pounds) the whole unit system will
change from metric to imperial units.
If the Device Mode [VoltGauge] is set, this parameter is deactivated
Unit
Parameter Range
Selection
Default
Min
Max
- -
-
N N