WARM-UP ALARM SETUP
The warm-up is not a true alarm but just a vocal alert that indicates when the main measures are in the green zones and so you
can take-off. To enable it select “VOICE” in the “Audio” parameter, otherwise select “NO” to disable it.
The measures monitored are: CAT, fuel pressure, oil pressure and temperature, all the CHTs.
6.1.8 Configuration menu
Menu auto-hide delay:
Set the time, in seconds, to automatically hide the menu if no buttons or knob are pressed.
Fuel/Timer panel auto-return delay:
Set the showing time, in seconds, of the Fuel Computer and hourmeter window (only for
ECLIPSE IFIS, see chap.8.3). After this time it return automatically to show the engine data window (set to zero to disable the
automatic return to engine data window).
Pitch adjust:
adjustment of the pitch to compensate the inclination of the instruments panel regards the longitudinal axis of the
aircraft. This function must be executed only once after installation, in leveled attitude. Rotate slowly the knob until the number at
the right become zero, then press it to store this value. Turn off and on the instrument after storing a new inclination value.
Roll adjust:
adjustment of the roll to compensate misalignments due to installation. Rotate slowly the knob until the number at
the right become zero, then press it to store this value. Turn off and on the instrument after storing a new inclination value.
RPM flight timer start threshold
: set the RPM required to start the flight timer (the flight timer start automatically when the
engine's RPM meets or exceeds this parameter for 30 seconds).
RPM counter multiplier
:ratio between pickup electrical pulses and engine's effective RPM.
(RPM counter multiplier = [# of pulses per driving shaft turn] * 60).
Local time is UTC
: Set the local time zone offset.
Turn rate indicator scale
: Set the full scale, in degrees/seconds, of the turn rate indicator.
6.1.9 Data log menu
See chap. 8.5 “Datalogger”.
6.1.10 About menu
On this screen is possible to read current software versions, useful to check if your ECLIPSE is updated to the latest version.
Note:
this manual is referred to the software version indicated on the first page. The version number to check is that indicated
after the word “
CORE:
”.
6.1.11 Firmware upgrade menu
This menu is for upgrading the firmware/software versions of your ECLIPSE, using a SD memory card (Secure Digital, use only
memory card with storage capacity not exceeding 2 Gb).
If you have the SD card with ECLIPSE firmware you can check or upgrade your ECLIPSE following this procedure:
- From the system setup menu, selecting “Firmware upgrade” will show the following screen: