DTX Series CableAnalyzer
Technical Reference Handbook
14-24
HDTDX Analyzer Specifications for Cables <100 m
(328 ft)
The specifications below are typical for cables less than
100 m (328 ft).
HDTDR Analyzer Specifications for Cables <100 m
(328 ft)
The specifications below are for HDTDR tests on cables less
than 100 m (328 ft) long.
Characteristic Impedance
The tester reports an estimate of the cable's impedance at
4 m from the beginning of the link. The accuracy of the
measurement is relative to a 100
Ω
terminating resistance.
Impulse Noise
Adjustable from 10 mV to 500 mV in 10 mV steps.
Monitors either polarity of noise on pair 3, 6.
Minimum detectable impulse width: 10 ns
Parameter
Twisted Pair Cable
Distance accuracy
±
(1 ft (0.3 m) + 2 % distance)
Distance resolution
1 ft or 0.1 m
Parameter
Twisted Pair Cable
Distance accuracy
±
(1 ft (0.3 m) + 2 % distance)
Distance resolution
1 ft or 0.1 m
Parameter
Twisted Pair Cable
Range
70
Ω
- 180
Ω
Accuracy
± (5
Ω
+ 5 % of
⏐
100
Ω
– Measured
⏐
)
Resolution
1
Ω
Summary of Contents for DTX-1800
Page 4: ......
Page 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Page 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Page 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Page 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Page 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Page 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Page 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Page 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...