![Fluke DTX-1800 Technical Reference Handbook Download Page 382](http://html.mh-extra.com/html/fluke/dtx-1800/dtx-1800_technical-reference-handbook_2309247382.webp)
DTX Series CableAnalyzer
Technical Reference Handbook
C-8
Modified 1 Jumper Method
This section shows modified reference and test connections
that produce 1 Jumper results. Use these connections if you
need 1 Jumper results but do not have connector adapters
that match the connectors on the fiber under test. This
method lets you connect to the fiber without disturbing the
fiber modules' output connections after setting the
reference.
Figures C-4 and C-5 show reference and test connections for
a fiber with MT-RJ connectors.
On the tester select 1 Jumper as the Test Method when
using modified 1 Jumper connections.