Diagnosing Fiber Cabling Faults
Diagnosing OTDR Test Failures
10-5
10
Diagnosing OTDR Test Failures
Table 10-3 describes some typical causes of fiber test
failures.
Table 10-3. Diagnosing OTDR Test Failures
-continued-
Overall Loss fails
•
There is one or more dirty or damaged connections in the cabling. Check the OTDR trace or event table for
high-loss reflective events.
•
The wrong fiber type is selected on the OTDR tab in Setup.
•
A patch cord, launch fiber, or fiber segment has the wrong core size, backscatter coefficient, or mode field diameter. If
the patch cords and launch fiber are the correct type, check the OTDR trace for mismatched cable in the cabling.
•
The cabling has a bad fusion or mechanical splice or a sharp bend. Use the OTDR trace or event table to locate these
faults.
•
The launch fibers have PC or UPC connectors, but the link being tested has APC connectors.
Note
OVERALL LOSS may show a WARNING if the first or last event is
hidden. If launch compensation was used, a WARNING occurs if the
launch event is hidden or if the event after the receive event is hidden.
Summary of Contents for DTX-1800
Page 4: ......
Page 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Page 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Page 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Page 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Page 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Page 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Page 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Page 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...