1 - 44
CHARACTERISTICS
CHARACTERISTICS
SPECIFICATION
ADDITIONAL
INFORMATION
1.20.5
Specification External trigger option
Valid for ext trig option in PM3384B/94B
(External trigger input is a standard feature in PM3370B/80B/90B)
SOURCE
SOURCE(S) MTB-triggering CH1 ... CH4
External
Line
INPUT CHARACTERISTICS
INPUT CONNECTOR
BNC
At rear of instrument
INPUT IMPEDANCE
Measured at freg.
<1MHz
R parallel - value
1 M
Ω
- tolerance
±
1%
C parallel - value
25 pF
- tolerance
±
5 pF
DYNAMIC RANGE
Up to 10 MHz
±
2.5V
Symmetrical
MAX. INPUT VOLTAGE
See note 1,2
Max. input voltage
150 V rms
According to
EN61010-1
Cat II Pol 2.
Note 1: Apparaturs should be properly grounded through the protective ground
conductor of the power cord.
Note 2: Up to 20 kHz; >20 kHz see figure 1.1.
SENSITIVITY
EDGE TRIGGER SENSITIVITY
See note 3
d.c. to 5 MHz
100 mV
d.c. to 10 MHz
200 mV
Note 3: In noise-trigger multiply stated value by 2.