V
-
Cursor measurements with 1% accuracies.
-
Extensive set of fully automated voltmeter and time measurement functions.
-
Probe operated ’Touch Hold and Measure’ function freezes the display and
instantly displays the signal frequency, amplitude and dc voltage level.
-
Peak detection for the capture of glitches as narrow as 5 ns.
-
Pattern, State and Glitch triggering (2 ns, only in the 4 channel models).
-
Event delay and pretriggering and posttriggering.
-
TV triggering including HDTV and TV line selection.
-
Serial interface for printing and plotting.
-
Averaging to reduce signal noise and to increase the vertical resolution from
8 to 16 bits.
-
Advanced mathematics, including digital low-pass filtering. A Math+ option
adds integration, differentiation, histogramming, and (as part of a option) FFT.
-
Sine interpolation and magnification which enables true to life four channel
single shot acquisitions with a timebase up to 625 ns/div (32x magnified)
-
A delayed timebase with full trigger features.
-
An EIA-232-D interface (standard) and an GPIB/IEEE-488 interface
(optional).
-
Autocal for automatic fine tuning of all circuitry to achieve maximum accuracy
under all user conditions.
-
Closed case calibration for efficient maintenance of traceable calibration at
minimum cost.
The following options are available:
-
A MATH+ option with more automated measurement functions including
envelope and measurement pass/fail testing. Also included in this option are
Integration, Differentiation, Histogramming, and FFT.
-
Memory extension offering 32K acquisition memory and the ability to store
204 traces (of 512 samples each) in memory.
-
IEEE-488.2 interface using the new SCPI (Standard Commands for
Programmable Instruments) industry standard for remote control of test and
measurement equipment.