
Remote Codes
Command Summary by Function
6
6-5
Table 6-1. Command Summary by Function (cont.)
Output Commands
FUNC?
Returns the present calibration function.
OL_TRIP?
Returns the detected state of scope overload protection.
OPER
Activates the 5820A output if it is in standby.
OPER?
Returns the operate/standby setting.
OUT
Sets the output of the 5820A and establishes a new reference point for the error
mode.
OUT?
Returns the output amplitudes and frequency of the 5820A.
OUT_IMP
Sets the output impedance of the SCOPE BNC.
OUT_IMP?
Returns the output impedance of the SCOPE BNC.
RANGE
Programs the range in PULSE, MEAS Z, and OVERLD modes.
RANGE?
Returns the present output ranges.
RANGELCK
Locks in the present range, or selects auto ranging.
RANGELCK?
Returns whether or not the preset output range is locked.
SCOPE
Sets the calibrator output to an oscilloscope mode.
SCOPE?
Returns the present oscilloscope mode.
STBY
Puts the 5820A in standby.
TDPULSE
Turns the tunnel diode pulse drive on or off in EDGE mode.
TLIMIT
Sets the OPERATE time limit for the OVERLD mode signal.
TLIMIT?
Returns the OPERATE time limit for the OVERLD mode signal.
TMWAVE
Selects the waveform for MARKER mode.
TMWAVE?
Returns the MARKER mode waveform setting.
*TRG
Triggers and returns a new impedance measurement.
TRIG
Sets the divider (and location if the 5-channel option is installed) of the signal at the
TRIG OUT BNC.
TRIG?
Returns the divider (and location if the 5-channel option is installed) of the signal at
the TRIG OUT BNC.
TRIGSKEW
Sets the skew between the trigger and the pulse outputs.
TRIGSKEW?
Returns the skew value between the trigger and pulse outputs.
VAL?
Returns the last impedance measurement value.
VIDEOFMT
Selects the format for VIDEO mode.
VIDEOFMT?
Returns the VIDEO mode format.
VIDEOMARK
Programs the VIDEO mode line marker location.
VIDEOMARK?
Returns the VIDEO mode line marker location.
WAVE
Sets the waveform for wavegen output.
WAVE?
Returns the waveform of the output.
ZERO_MEAS
Sets the measurement offset to the capacitance value.
Summary of Contents for 5820A
Page 10: ...5820A Operators Manual vi ...
Page 14: ...5820A Operators Manual x ...
Page 16: ...5820A Operators Manual 1 2 ...
Page 32: ...5820A Operators Manual 2 2 ...
Page 40: ......
Page 144: ...5820A Operators Manual 6 2 ...
Page 190: ......
Page 212: ...5820A Operators Manual 7 24 ...
Page 214: ...5820A Operators Manual 8 2 ...
Page 230: ...5820A Operators Manual 9 2 ...
Page 234: ...5820A Operators Manual ...
Page 244: ...5820A Operators Manual A 10 ...
Page 245: ...B 1 Appendix B ASCII and IEEE 488 Bus Codes ...
Page 246: ...5820A Operators Manual B 2 ...
Page 248: ...5820A Operators Manual B 4 ...
Page 250: ...5820A Operators Manual C 2 ...
Page 258: ...5820A Operators Manual E 4 ...
Page 264: ...5820A Operators Manual F 6 ...
Page 272: ...5820A Operators Manual 8 ...