50
10.
Servicing the Charging
Station
To access the charging station for servicing purposes, follow the instructions below:
10.1.
250 A Circuit
1.
Unlock the lock on the pedestal access door latch, if applicable.
2.
Remove the pedestal access door screws, if applicable, and open the door.
3.
Put the breaker in the OFF position.
4.
Confirm that there is no voltage in the charging station.
5.
Put the breaker lock arm in the up position (if installed).
6.
Secure the breaker lock arm by placing a padlock (not included) in the opening. When done, the
breaker lock arm should be locked in the up position (if installed).
7.
The charging station can now be accessed for servicing.
To put the charging station back in operation, follow the steps below:
1.
Remove the padlock on the breaker lock (if installed).
2.
Put the breaker lock arm in the down position (if installed).
3.
Put the breaker in the ON position.
4.
Ensure that the power on the charging station is ON and that the charging station is working properly.
5.
Secure the access door according to regulations either by:
a.
Placing a padlock (not included) on the door latch opening.
b.
Tightening the 2 tamper-resistant hex drive screws on the top of the access door.
Breaker lock in the down position
Breaker lock in the up position
Summary of Contents for CoRe+
Page 1: ...1 x Pedestal and Cable Management System Installation Guide TM ...
Page 8: ...8 3 1 2 Dimensions The image below shows the dimensions of the pedestal ...
Page 24: ...24 Measurements for the CoRe MAXon a Wall Mounted Installation ...
Page 47: ...47 9 2 Multiple Pedestals Multiple Devices on Separate Electrical Circuits Grounding ...