7 — Technical specifications
]
ThermaCAM™ PM575/595
Operator’s Manual
44
7
Technical specifications
7.1
General specifications
Object temperature measurement
range (PM595):
-40—+500 ºC (-40—+930 ºF), two ranges. Up to
+2000 ºC (+2700 ºF) with high temperature option.
Object temperature measurement
range (PM575):
-20—+500 ºC (-4—+930 ºF), two ranges. Up to
+1000 ºC (+1832 ºF) with high temperature option.
Measurement accuracy:
± 2 %
Thermal sensitivity:
< 0.1 ºC
Field of view (F x V):
See “Lens data” on page 48.
Detector type:
Focal Plane Array
(
FPA
), uncooled microbolometer,
320 x 240 pixels.
Spectral range:
7.5—13 µm, built-in atmosheric filter with cut-on
@ 7.5 µm.
Video output:
Standard VHS or S-VHS.
Viewfinder:
Colour LCD (
TFT
)
PC-card drive:
One slot for
Type II
or
Type III
PC-cards. Either
FLASH
cards or hard disks (
ATA
-compatible) can be used.
Summary of Contents for ThermaCAM PM575
Page 1: ...ThermaCAM PM575 595 Operator s Manual ...
Page 3: ...ThermaCAM PM575 595 FLIR Systems AB May 1999 Publ No 557 369 Ed A Operator s Manual ...
Page 4: ......
Page 16: ... 3 2 Connections ThermaCAM PM575 595 Operator s Manual 8 Figure 3 2 Camera connectors ...
Page 67: ......
Page 68: ......