5.5.4.2.4 — Saturation col.
]
ThermaCAM™ PM575/595
Operator’s Manual
38
5.5.4.2.4
Saturation col.
Saturation colour is an on/off function. If
On
is selected the areas that contain
temperatures outside the present level/span settings are coloured with the satura-
tion colours. The saturation colours contain an »overflow« colour and an »under-
flow« colour.
There is also a third red saturation colour that marks everything saturated by the
detector indicating that the range should probably be changed.
5.5.4.2.5
Data field
This parameter determines the amount of data/information that will be shown on
the screen. There are four levels:
Reduced, Normal, Extended
and
None
.
Figure 5.21
Extended data presentation.
In
Reduced
mode, only the lower line is displayed. In
Normal
mode the lower and
middle lines are displayed. In
Extended
mode all three lines are displayed.
• The lower line contains information on the date, time, emissivity and zoom factor.
• The middle line contains information on filter setting (optional) and lenses. If no
filter is enabled, the text
Filt = NOF
is displayed. If a high temperature filter is
enabled, the text
Filt = AP1
is displayed. The lense that is currently being used
is indicated as
FOV 12, FOV 24
or
FOV 45
¸ e.g. 12°, 24° and 45° field of view,
respectively. In this line the selected temperature range is also displayed, i.e.
35–1000 °C (95–1832 °F) or -40–350 °C (-40–662 °F).
• The upper line contains information on the current directory, ambient tempera-
ture, relative humidity and object distance.
5.5.4.2.6
Data background
The background of the data can be selected as
Transparent
or
Solid
. If
Transpar-
ent
is selected, the data fields are displayed using the infrared image as a back-
ground. If
Solid
is selected, the data fields are displayed against a near-white
background.
5.5.4.2.7
Text comments
The text comments option can be selected as
None, Value only
and
Label & value
.
If
Value only
is selected, the text comments at the bottom of the screen show only
the user-defined values that the operator has selected when the text comments
were created, e.g. recommendations for repair. If
Label & value
is selected, both
Summary of Contents for ThermaCAM PM575