8.1.4
Connection of the transducer cable to the junction box
For the connection of the transducer cable with SMB connectors (connection system TS), see section 8.1.4.1.
For the connection of the transducer cable with a plastic cable jacket and stripped cable ends (connection system TS), see
section 8.1.4.2.
For the connection of the transducer cable with a stainless steel conduit and stripped cable ends (connection system TS),
see section 8.1.4.3.
8.1.4.1
Transducer cable with SMB connectors
• Remove the blind plug on the right side for the connection of the transducer cable (see Fig. 8.8).
• Insert the transducer cable with the SMB connectors into the junction box.
• Fix the transducer cable by tightening the cable gland.
• Connect the SMB connectors to the sockets of the junction box (see Fig. 8.8 and Tab. 8.7).
8.1.4.2
Transducer cable with plastic cable jacket and stripped cable ends
• Remove the blind plug on the right side for the connection of the transducer cable (see Fig. 8.10).
• Open the cable gland of the transducer cable. The compression part remains in the cap nut (see Fig. 8.9).
• Push the transducer cable through the cap nut and the compression part. Prepare the transducer cable.
• Shorten the external shield and brush it back over the compression part.
• Screw the sealing ring side of the basic part tightly into the junction box.
• Insert the transducer cable into the junction box.
Attention!
Observe the "Safety instructions for the use in explosive atmospheres" (see SIFLUXUS document).
Tab. 8.7: Terminal assignment
terminal
connection
XV
SMB connector (brown cable, marked white)
XR
SMB connector (brown cable, marked black)
Fig. 8.8: Connection of the transducer cable with SMB connectors
Attention!
Observe the "Safety instructions for the use in explosive atmospheres" (see SIFLUXUS document).
Attention!
For good high frequency shielding, it is important to ensure good electrical contact between the exter-
nal shield and the cap nut (and thus to the junction box).
SMB connector
transducer cable
cable gland
junction box JB02, JB03
Summary of Contents for FLUXUS WW
Page 1: ...User manual UMFLUXUS_WWV1 1EN Ultrasonic flowmeter for water and wastewater FLUXUS WW...
Page 4: ...FLUXUS WW UMFLUXUS_WWV1 1EN 2018 02 28...
Page 8: ...FLUXUS WW Table of contents 8 UMFLUXUS_WWV1 1EN 2018 02 28...
Page 144: ...FLUXUS WW D Conformity declarations 144 UMFLUXUS_WWV1 1EN 2018 02 28 D Conformity declarations...
Page 145: ......
Page 146: ......