background image

reedinstruments

www

com

Model

R8100

Video Inspection Camera

Instruction

Manual

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

1.800.868.7495

[email protected]

REED-Direct.ca

Summary of Contents for R8100

Page 1: ...uments www com Model R8100 Video Inspection Camera Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 1 800 868 7495 nfo REED Direct ca REED Direct ca ...

Page 2: ...30 5 Pantone 485 Red 10 100 100 5 Table of Contents Safety 3 Features 3 Specifications 3 4 Instrument Description 4 Operating Instructions 5 6 LED Brightness Adjustment 5 Zoom 5 Display Rotation 5 Additional Gooseneck Installation 6 Accessory Installation 6 Battery Indicator 6 Battery Replacement 7 For service on this or any other REED product or information on other REED products contact REED Ins...

Page 3: ...own Clean the camera after each use Do not use detergents to clean this instrument When storing the instrument for a long period of time remove the batteries to avoid battery fluid leaking and damaging the instrument The gooseneck angle should not pass 90 or it will lose it s flexibility Features High visibility adjustable LED lighting Real time 4 2 colour TFT LCD monitor with 480 x 234 pixel reso...

Page 4: ...olor TFT LCD Size 2 4 inch Display Resolution 480 x 234 Active Area 48mm x 35 6mm Power Supply 4 x AA Operating Temperature 0 to 45 C Storage Temperature 20 to 60 C Relative Humidity 5 to 85 Includes Video borescope imager head magnet hook and mirror attachments and batteries Optional Accessories 6 Cable Extension BS C6 9mm Replacement Camera Head with 3 Cable BS 15 9C3 Instrument Description 1 Po...

Page 5: ...nstrument on The screen will display the start up screen indicating that it has turned on To turn the instrument off press the power button again LED Brightness Adjustment Press the LED Brightness Button to adjust the brightness of the LED Press and hold the LED Brightness Button to fast adjust it up and down Zoom Press the Zoom Button to zoom in 2X Press the button again to zoom back to 1X Displa...

Page 6: ... to install additional goosenecks on the instrument Be sure to not under or over screw the connection covers Maximum gooseneck length is 30 feet 9 144 meters Accessory Installation To install the mirror hook or magnet follow the diagrams below Battery Indicator The Battery Indicator on this instrument changes colour to help indicate the battery status When the indicator turns red the batteries wil...

Page 7: ... Blue 100 80 30 5 Yellow 0 27 100 0 Red 10 100 100 5 Yellow 0 27 100 0 Blue 100 80 30 5 Only if you REALLY need them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Battery Replacement Follow the images below to change the instruments batteries Be sure to match up the polarity properly 1 800 868 7495 nfo REED Direct ca REED Direct ca ...

Page 8: ..._______________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _________________...

Reviews: