11 Displaying measured values
79
All channels
The measured values of all channels (measuring and calculation channels) are displayed. The next active channel is se-
lected after min. 1.5 s.
Only calculation channels
Only the measured values of the calculation channels are displayed. The next active calculation channel is displayed after
min. 1.5 s.
This mode can only be activated if at least 2 calculation channels are active.
11.2.2
HumanMux mode
In the HumanMux mode, the measured values of one channel are displayed. The measurement on the other channels is
continued, but not displayed.
Press key
to display the next activated channel. The measured values of the selected channel will be displayed as
configured in the program branch
Output Options
(see section 11.1).
11.3
Adjustment of the display
During the measurement, the display can be adapted in order to display 2 measured values at the same time (one in each
line of the display). This does not affect totalizing, storing of measured values, transmission of measured values, etc.
The following information can be displayed in the upper line:
The measured values of the physical quantity selected in the program branch
Output Options
can be displayed in the
lower line:
Press key
during the measurement to change the display in the upper line, press key
to change the display in
the lower line.
The selected channel is displayed left in the upper line.
display
explanation
Thermal energy=
designation of the physical quantity
A: +18.8 kWh
values of the totalizers, if activated
Tx=
temperatures assigned to the channel and their difference if the temperature is measured
full=
date and time at which the data logger will be full, if activated
Mode=
measuring mode
L=
transducer distance
Rx=
alarm state indication if it is activated (see section 16.6.5) and if alarm outputs are activated (see
section 16.5).
δ
c=
difference between the measured sound speed and the sound speed of a selected reference flu-
id, if activated (see section 14.3)
status line (see section 11.4)
display
explanation
12.3 m/s
flow velocity
1423 m/s
sound speed
124 kg/h
mass flow rate
15 m3/h
volumetric flow rate
The character
*
indicates that the displayed value (here: flow velocity) is not the selected
physical quantity.
B:Flow Velocity
1.25
m/s
A:Flow Velocity
*
2.47
m/s
Summary of Contents for FLUXUS WW
Page 1: ...User manual UMFLUXUS_WWV1 1EN Ultrasonic flowmeter for water and wastewater FLUXUS WW...
Page 4: ...FLUXUS WW UMFLUXUS_WWV1 1EN 2018 02 28...
Page 8: ...FLUXUS WW Table of contents 8 UMFLUXUS_WWV1 1EN 2018 02 28...
Page 144: ...FLUXUS WW D Conformity declarations 144 UMFLUXUS_WWV1 1EN 2018 02 28 D Conformity declarations...
Page 145: ......
Page 146: ......