A Menu Structure
142
UMFLUXUS_G8V4-6-1EN, 2018-10-10
the coefficient memory is being partitioned
SYSTEM settings\Libraries\Extended Library
selection of the displays for the activation of the extended library
Activation of the Extended Library
x
SYSTEM settings\Dialogs/Menus
selection of the displays for the activation/deactivation or setting of the menu
items in the other program branches
activation of the menu item for the input of the pipe circumference in the pro-
gram branch
Parameter
x
activation of the menu item for the input of the fluid pressure in the program
branch
Parameter
This display will only be indicated if
SYSTEM settings
\
Measuring
\
Gas-
Measuring
is deactivated.
x
selection of the input mode for the measuring point number in the program
branch
Measuring
:
(1234)
: digits, point, hyphen
(
↑↓←
→
)
: ASCII editor
x
setting for the display for the input of the transducer distance in the program
branch
Measuring
:
•
user
: Only the entered transducer distance will be displayed if the recom-
mended and the entered transducer distances are identical.
•
auto
: Only the recommended transducer distance will be displayed.
recommended setting:
user
x
selection of the error value delay
•
damping
: The damping factor will be used.
•
edit
: The menu item for the input of the error value delay in the program
branch
Output Options
will be activated.
x
activation of the display of the alarm state during the measurement
x
selection of the unit of measurement for the length
x
selection of the unit of measurement for the temperature
x
selection whether the absolute pressure p
a
or relative pressure p
g
is to be
used
x
selection of the unit of measurement for the pressure
x
INIT-resis-
tant
FORMATTING ...
■■■■■■
...
Libraries
↕
Extended Library
Extended Library
off
>ON<
SYSTEM settings
↕
Dialogs/Menus
Pipe Circumfer.
off
>ON<
Fluid pressure
off
>ON<
Meas.Point No.:
(1234) >(
↑↓←
→
)<
Transd. Distance
auto
>USER<
Error-val. delay
damping
>EDIT<
SHOW RELAIS STAT
off
>ON<
Length unit
>[mm]<
[inch]
Temperature
>[°C]<
[°F]
Pressure absolut
off
>ON<
Pressure
>[bar]<
[psi]