7. Pour concrete into the recesses in the concrete foundation for the foundation blocks.
8. After the concrete has set, tighten the fastening bolts of the foundation blocks with the
specified tightening torque (Page 77).
9. Record the alignment dimensions and keep the report in a safe place together with these
operating instructions.
NOTICE
Damage caused by unevenly tightening the fastening bolts
The gear unit can be damaged by unevenly tightening the fastening bolts.
Evenly tighten the fastening bolts. Ensure that the gear unit is not deformed or distorted when
tightening the fastening bolts.
Mounting on a concrete foundation using anchor bolts
Requirements
The lower side of the gear unit mounting feet must be clean.
Inserting the anchor bolt
The following diagram shows the inserted anchor bolt:
①
Baseplate
⑤
Anchor bolt
②
Support
⑥
Pressure plate
③
Fine-grout concrete
⑦
Wood
④
Raw foundation
⑧
Hexagon nut
Figure 5-4
Inserted anchor bolt
Proceed as follows to insert the anchor bolt:
1. Place the support on the baseplate embedded in the fine-grout concrete.
2. Insert the anchor bolt.
Mounting
5.3 Gear unit mounting
REDUREX Gear unit 5200en
60
Operating Instructions 03/2019
Summary of Contents for K.A Series
Page 2: ...07 03 2019 13 01 V4 00...
Page 10: ...Table of contents REDUREX Gear unit 5200en 10 Operating Instructions 03 2019...
Page 44: ...Description 3 16 Auxiliary drive REDUREX Gear unit 5200en 44 Operating Instructions 03 2019...
Page 82: ...Mounting 5 9 Final work REDUREX Gear unit 5200en 82 Operating Instructions 03 2019...
Page 104: ...Maintenance 8 4 Possible faults REDUREX Gear unit 5200en 104 Operating Instructions 03 2019...
Page 106: ...Service Support REDUREX Gear unit 5200en 106 Operating Instructions 03 2019...
Page 108: ...Disposal REDUREX Gear unit 5200en 108 Operating Instructions 03 2019...
Page 110: ...Spare parts REDUREX Gear unit 5200en 110 Operating Instructions 03 2019...
Page 126: ...Index REDUREX Gear unit 5200en 126 Operating Instructions 03 2019...
Page 127: ......