A taconite seal is illustrated in the diagram below:
①
Grease nipple
③
Labyrinth, filled with grease, can be regreased
②
Lamellar seal
④
Rotary shaft sealing ring
Figure 3-8
Taconite‐seal
3.6.4
Tacolab seal
Application
Only use Tacolab seals with pressure lubrication and with a reduced oil level.
Features
Tacolab seals are non-contact, low-maintenance seals that do not wear. It is not therefore
necessary to interrupt operation in order to service or replace them.
The Tacolab seal is a combination of two sealing elements:
● Labyrinth seal comprising two labyrinth sealing rings to prevent the escape of lubricating oil
● Grease-filled dust seal (comprising a labyrinth and a lamellar seal) to allow operation of the
gear unit in extremely dusty environments
Description
3.6 Shaft seal
REDUREX Gear unit 5200en
Operating Instructions 03/2019
27
Summary of Contents for K.A Series
Page 2: ...07 03 2019 13 01 V4 00...
Page 10: ...Table of contents REDUREX Gear unit 5200en 10 Operating Instructions 03 2019...
Page 44: ...Description 3 16 Auxiliary drive REDUREX Gear unit 5200en 44 Operating Instructions 03 2019...
Page 82: ...Mounting 5 9 Final work REDUREX Gear unit 5200en 82 Operating Instructions 03 2019...
Page 104: ...Maintenance 8 4 Possible faults REDUREX Gear unit 5200en 104 Operating Instructions 03 2019...
Page 106: ...Service Support REDUREX Gear unit 5200en 106 Operating Instructions 03 2019...
Page 108: ...Disposal REDUREX Gear unit 5200en 108 Operating Instructions 03 2019...
Page 110: ...Spare parts REDUREX Gear unit 5200en 110 Operating Instructions 03 2019...
Page 126: ...Index REDUREX Gear unit 5200en 126 Operating Instructions 03 2019...
Page 127: ......