14. Dispensing tube removal
To Remove and Replace Dispensing Tube:
1. Drain the flavor from the tank in the dispenser.
•
Place a catch container under the Product Dispensing Block to catch the
drain.
•
Press
the
Flavor
button for the tank to be changed.
•
Press
the
Clean
button to drain the tank.
•
NOTE: The drained flavor may be returned to the tank after the tube is
replaced, if you are using the same flavor. If you are changing flavors, the
drained flavor should be discarded.
2. Clean the tank, following instructions on page 17, if you are changing flavors.
•
Make sure you rinse, clean, rinse and sanitize.
3. Remove the tube for the old flavor or the damaged tube:
•
If you are replacing the tube, twist the tube off the barb.
•
Pull the other end of the tube off its product dispensing block fitment.
4. Replace with the new tube
•
Attach the other end of the tube to the product dispensing block fitment.
5. Load new flavor into the tank. If you are not changing flavors, you may reload
the flavor you drained in step 1. See Instructions, pages 8-10.
6. Reset the tank:
•
Close the dispenser door.
•
Press
the
Flavor
button for the tank that was filled.
•
Press
the
Reset
button on the upper front door of the dispenser.
7. Prime the pump.
•
Place empty cup or container under the product dispense block
•
Press the individual flavor button
•
Press
the
Prime
button and hold for 2 seconds.
Summary of Contents for AC-FS5
Page 1: ...AC FS5 Service Manual D 19 022...
Page 27: ...27 Tanks Removal...
Page 41: ...41 IV DRAWINGS WIRING DIAGRAM...
Page 42: ...42 Shelf Assembly FlavorShot 5...
Page 43: ...43 Tubing Clear PVC Assembly FlavorShot 5...
Page 44: ...44 Outer Body Assembly FS 5...
Page 45: ...45 General Assembly FS 5...