![FlavorShot AC-FS5 Service Manual Download Page 26](http://html1.mh-extra.com/html/flavorshot/ac-fs5/ac-fs5_service-manual_2303451026.webp)
26
6. Front Door – door cord removal / Replacement
To Remove and Replace Front Door Cord:
1. Disconnect the door cord, which enters the door at a connection at the lower
left corner of the door.
•
Depress the connect tab with a small screw driver
•
Pull the cord out of the connection jack in the door
2. Remove the Catch Tray.
3. Remove the lower front panel by removing its 4 screws.
4. Remove the back panel by removing its 8 screws.
5. Locate the door cord at the back of the dispenser.
6. Remove its ground wire from the ground post.
7. Disconnect the door cord connector.
8. Discard the cord.
9. Install a new cord – in the reverse order of the removal.
•
Make sure the cord is secured with wire ties.
7. Tank removal
To Remove a Flavor Tank:
1. Remove all flavor from the tank.
•
Place a container under the product dispensing block to catch any residual
flavor and to prevent spills.
•
Press
the
Flavor
button for the tank to be removed and then press and
hold the
Clean
button for 2 seconds to empty the pump system of residual
product. The Clean button is located on bottom of the button panel on the
dispenser door.
2. When the tank and pump are empty, press the
Clean
button again to cancel
the remainder of the clean cycle.
3. Open the dispenser door and slide the tank shelf forward.
4. Lift up the empty flavor tank to dislodge it from the front tank fitment in the
pump body and remove it.
5. Examine the O-ring on the fitment for possible damage, e.g. scrapes, cracks,
buildups, looseness. If damaged, the tank will leak and the O-ring must be
replaced.
6. Rinse, wash, rinse, and sanitize the flavor tank, following the instructions in
“Cleaning FlavorShot tank and cap”, page17.
NOTE:
•
Always
clean empty tanks before re-using or storing them.
•
Follow the “Install & Fill a Flavor Tank” instructions on page 8 when you
place an empty tank in the dispenser.
•
Before installing a flavor tank, apply a small amount of food-grade
lubricant to the O-ring on the outlet at the bottom of the tank.
Summary of Contents for AC-FS5
Page 1: ...AC FS5 Service Manual D 19 022...
Page 27: ...27 Tanks Removal...
Page 41: ...41 IV DRAWINGS WIRING DIAGRAM...
Page 42: ...42 Shelf Assembly FlavorShot 5...
Page 43: ...43 Tubing Clear PVC Assembly FlavorShot 5...
Page 44: ...44 Outer Body Assembly FS 5...
Page 45: ...45 General Assembly FS 5...