Primo.Neb
Mod. P0403EM F400
AEROSOL THERAPY DEVICE
Congratulations on your purchase and thank you for choosing our unit. Our goal is to
fully satisfy our customers by offering them cutting-edge products for treating ailments
of the respiratory system.
Please read these instructions carefully and keep them
handy for future reference. Use this device only as described in this manual. This
is a home medical device for the nebulization and administration of medication
prescribed or suggested by your doctor.
Please visit
www.flaem.it
to see our entire
range of Flaem products.
THIS DEVICE COMES EQUIPPED WITH:
A -
Aerosol Therapy Device
A1 - Switch
A2 - Air outlet port
A3 - Air filter
A4 - Nebulizer port
A5 - Power cord
C -
Accessories
C1 - RF7 Dual Speed Nebulizer
C1.1 - Bottom piece
C1.2 - Nozzle
C1.3 - Top piece
C1.4 - Speed selector
C2 - Mouthpiece
C3 - SoftTouch
adult mask
B -
Connection tube (main unit /
nebulizer)
IMPORTANT SAFEGUARDS
• Before using the device for the first time and periodically during the product’s life,
check the integrity of its structure and of the power cable, making sure that there is no
damage; if it is damaged, do not insert the plug and take the product immediately to an
authorised FLAEM technical assistance centre or to your local dealer.
• The average life span of accessories is 1 year; however, we recommend you replace
the nebulizer every 6 months in intensive use (or earlier, if the nebulizer is blocked) to
always ensure maximum therapeutic effect.
• Children and disabled persons should always use the unit under strict supervision of an
adult who has read this manual.
• Several parts of the device are small enough to be swallowed by children; therefore
keep the device out of reach of children.
• Do not use the tubes and the cords of the device for purposes other than those specified
as they may cause strangulation hazard; utmost attention must be paid to children
and persons with special needs; usually, such persons are not capable of assessing the
hazard correctly.
• The unit should not be used in the presence of anaesthetic mixture inflammable with
air, oxygen or nitrous oxide.
• Keep the cord away from heated surfaces.
• Keep the power supply cord away from animals (for example rodents) as they may
damage the insulation of the power supply cord.
• Do not handle the unit with wet hands. Do not use the device in humid environments
(e.g. while taking a bath or shower). Do not immerse the device in water; should this
accidentally occur, unplug the device immediately. Do not remove or touch the device
immersed in water before pulling out the plug. Take the device immediately to an
authorized service center or to your local dealer.
• Only use the device in dust-free environments; otherwise, therapy may be compromised.
• The casing of this unit is not protected against the penetration of liquids. Do not wash
the device under running water or submerge in water. Keep away from splashing water
or other liquids.
• Do not expose the device to high temperatures.
• Do not put the device near heat sources, direct sunlight, or in hot environments.
• Do not obstruct or insert any objects in the filter or in its housing.
• Do not obstruct the air vents placed on both sides of the unit.
• During use, always place the unit on a firm surface clear of obstacles.
• Check that there is no material obstructing the air vents before each use.
• Do not place any objects inside the air vents.
• The average duration provided for compressor ranges is: F400: 400 hours, F700: 700
hours, F1000: 1000 hours, F2000: 2000 hours.
• Repairs must be performed by authorized personnel only. Any unauthorized repairs will
void the warranty and may pose a safety hazard for the user.
WARNING: Do not modify this equipment without authorization of the manufacturer
• The Manufacturer, the Retailer and the Importer are responsible for the safety, reliability
and performance of the device only if: a) the device is used in accordance with the
operating instructions b) the electrical system of the premises where the device is used
is in compliance with current laws.
• Interactions: The materials used that come into contact with medications have been
tested with a wide range of medications. However, due to the variety and continuous
evolution of medication, the possibility of a chemical interaction cannot be excluded.
We recommend that once the medication has been opened you should use it as soon
as possible and avoid prolonged contact of the medication with the nebulizer.
• The manufacturer should be contacted for reporting problems and/or unexpected
events related to device operation.
OPERATING INSTRUCTIONS
Before each use, clean hands thoroughly and clean the device as described in the
section on “CLEANING SANITIZATION DISINFECTION". During use, it is advisable to
protect yourself from any dripping. It is recommended that each person use their
own nebulizer cup and accessories to prevent risk of infection due to contamination.
During application it is advisable to suitably protect yourself from any dripping.
1. Plug the power cord (A5) into a power socket corresponding to the voltage of the unit.
This must be positioned so that it is not difficult to make the disconnection from the
mains.
2. Insert the nozzle (C1.2) in the upper part (C1.3) pressing as shown by the 2 arrows in
the “Connection diagram” in point C1. Insert the Speed selector (C1.4) in the upper part
(C1.3) as shown in the “Connection diagram” in point C1. Pour the medication prescribed
by the doctor into the lower part (C1.1). Close the nebuliser by turning the upper part
(C1.3) clockwise.
3. Connect accessories as indicated in the “Connection diagram” on the cover.
4. Sit comfortably holding the nebuliser in your hand, place
the mouthpiece onto your mouth or alternatively use the
nose piece or mask. Should you opt for the mask accessory,
place it on your face as shown in the picture (with or
without using the elasticated strap).
5. Turn on the device using the switch (A1) and then breathe
in and exhale deeply.
6. When the treatment is finished, shut off the device and
unplug the power cord.
WARNING:
If after the therapy session moisture accumulates
in the tube (B), remove the tube from the nebulizer and dry it using the device’s
ENGLISH
8
9
Summary of Contents for P0403EM F400
Page 2: ...Si ob ist de e LA A B P la ch d d L l a se In za A g N tr p co a Te Te ta N ti n l a a...
Page 46: ...F400 400 F700 700 F1000 1000 F2000 2000 b _ 1 2 3 4 5 6 44...
Page 49: ...C1 1 C1 2 C1 3 C1 4 C2 C3 10 C C1 1 C1 2 C1 3 C1 4 C2 C3 6 3 Flaem 47...
Page 53: ...FLAEM A5 1 C1 3 C1 2 2 C1 3 C1 4 C1 C1 1 C1 C1 3 3 4 A1 5 6 B 51...
Page 54: ...SoftTouch SoftTouch C1 4 MAX MIN C1 4 Dual Speed RF7 Dual Speed RF7 A3 Flaem 52...
Page 58: ...2 2007 1 60601 60 EN EMC RE Flaem www flaemnuova it CE 19 2012 CE 19 2012 56...
Page 59: ......