Lit. No. 44224, Rev. 14
94
August 15, 2011
HYDRAULIC SYSTEM
Fluid Level
NOTE: On XtremeV™ and XLS™ blades, add
fl
uid only when all rams are retracted.
NOTE: Remove
fi
ll plug slowly to relieve any
pressure in reservoir.
MAINTENANCE
CAUTION
Do not mix different kinds of hydraulic
fl
uid. Some
fl
uids are not compatible and
may cause performance problems and
product damage.
HT Series™ Blades:
With the system attached to
the vehicle, activate the control. Lower the blade
to the ground and turn OFF the control. Remove
the
fi
ll plug. Fill the reservoir to within 2-1/2" of the
top of the
fi
ll hole. Replace the
fi
ll plug.
Drain Plug
HT Series Blades
Breather/Fill Plug