7.11 TEMPERATURE
SETTINGS
PC Setting
32
o
F 32.9
o
F 33.8
o
F 34.7
o
F 35.6
o
F 37.4
o
F 39.2
o
F 41.0
o
F 42.8
o
F 44.6
o
F 46.4
o
F
Colder
Warmer
FC Setting
-5.8
o
F -5.8
o
F -4
o
F -3.1
o
F -1.3
o
F 0.0
o
F 1.4
o
F 2.3
o
F 4.1
o
F 5
o
F 6.8
o
F
Colder
Warmer
Default factory settings are 37.4
0
F for the provision compartment and 0
0
F for the freezer compartment.
Note: Crowbar setting for the PC is 28.4
0
F and for the FC is –14.8
0
F. Temperatures shown are average
temperatures.
7.12
INTERNAL AIR FLOW
The freezer fan draws air through the evaporator and into a duct in the rear wall of the freezer compartment.
This air exits through the fan grill at the top of the freezer compartment. The air behind the freezer coil cover
is also diverted through the divider partition to another fan, which supplies the cold air into the PC
compartment. The amount of air is controlled electronically by two sensors, which in turn regulate the speed
of both PC and FC fans to maintain selected temperatures in each compartment.
Air from the PC returns to the FC evaporator by way of the return air duct, which is built into the divider
partition. This air is drawn across the evaporator by the evaporator FC fan motor to be recirculated again
throughout the PC / FC compartments.
7.13 DIAGNOSTICS
A spanner symbol and LCD fault code will appear automatically if there is a fault in the temperature measuring
system, defrost system, fans or low ambient heater. (Refer diagram below)
When the PC door is opened, an alarm will sound. The number of beeps also indicates the fault code.
Pressing any of the control buttons can deactivate these alarms.
Example: When a fault develops, the LCD fault code appears with the spanner.
After rectifying the problem, the fault code and spanner will disappear. Faults are only rectified when that
feature is used. So in the case of a defrost fault, the code will remain until a defrost is initiated and it is
successful.
7.14 FAULT
CODES
Fault Code 1
Reason:
On the last power up, the power module failed self-test.
Primary Action: Replace power module.
Fault Code 2
Reason:
The previous 2 defrosts were aborted after
40 minutes.
Primary Action:
Check defrost element assembly in the FC. If faulty, replace.
Fault Code 3
Reason:
The resistance of all the temperature sensors are outside the normal range. (> 45K
Ohms)
Primary Action:
Check the 6-way RAST connector at the power module.
Secondary Action:
Re-terminate the 6-way RAST connector.
Tertiary Action:
Replace the power module.