819091D
46
10.7
TO RESET THE FILTER ICON
Press the UP + LOCK button for 4 seconds to reset the “Filter monitor”.
Note: Do not reset the monitor before the filter is changed, or monitoring will be inaccurate.
10.8
TO DISABLE THE FILTER ALARM (Products before January 2009)
Disable the alarm if no filter is to be fitted.
Press and hold the MEASURED FILL button, and press and hold the MENU and UP buttons for 4 seconds to
turn this feature on/off.
10.9
FLOWMETER CALIBRATION / MEASURED FILL CALIBRATION
(Products before January 2009)
This calibration is to be carried out when the set quantities may be under or over the default settings.
Example: Default setting is 250 mls/8fl ozs, however only 200 mls/7fl ozs is being dispensed.
Press and hold the MEASURED FILL button, then press the DOWN button to enter the calibration mode.
100 CAL will be displayed in the MEASURED FILL window.
The 100 display is a percentage. It can be increased by using the UP button, or decreased by using the
DOWN button.
10.10 TO DISABLE THE FILTER ALARM (Products after January 2009)
Disable the alarm if no filter is to be fitted.
Press and hold the
MENU
+
UP
+
LOCK
buttons for 4 seconds to turn this feature on/off.