Installation Instructions
Panda 14.000 NE PVK-U S00420 - Chapter E: Installation Instructions Page 65
E.2.1 Voltage control system
The VCS control is used for the adjustment of the number of revolutions of the engine and thus
the voltage of the generator. It belongs to the accessories and is externally attached.
VCS-printed board
1
4
2
3
6
7
5
1. Connection measuring voltage
2. Adjustment booster voltage (do not adjust!)
3. Adjustment VCS-voltage
4. Connection VCS inlet
5. Electrical fuse (1,6A slow to blow)
6. Potentiometer for booster time
7. Connection for PC