Maintenance Instructions
Panda 14.000 NE PVK-U S00420 - Chapter C: Maintenance Instructions Page 39
5.) The injection line must be raised some
millimeters.
6.) Main power switch "OFF".
C.4.1 Exchange of the fuel filter
The exchange of the filter depends on the
contamination of the fuel, should take
place at least all 300 operation hours.
Before the exchange of the filter the inlet
must be clamped.
Remove the hoses from the used filter and
fasten them to the new filter. The arrow on
the filter housing indicates the direction of
the fuel flow. A clogged filter causes a
decreased power output of the generator