C.1 Maintenance Requirements
Control before starting
• Oil level
• Cooling system leaks
• Visual check for any changes, leaks oil drain system, v-belt, cable connections, hose clips, air
filter, fuel lines
Once a week
• Lubrication of actuator-trapezoid thread spindle
For Maintenance Intervalls see Table F.1, “Maintenance intervalls,” on Page I
C.2 Oil Circuit Maintenance
The laid down intervals must be heeded in order to avoid serious damage to the motor!
The first oil change should be carried out 35 hours after running time. Thereafter every 100 hours.
SAE 30 is to be used for temperatures over 20°C and SEA 20 for temperatures between 5°C and
20°C. Viscosity SAE 10W or 10W-30 is laid down for temperatures below 5°C.
Type and amount of required oil see:
Table F.2, “Engine oil,” on Page II and Table F.5, “Technical Data Engine,” on Page IX
An oil drainage hose is fitted in the sound
cover for changing the oil. This is fed
through the capsule to the outside.
Open the pass-through cover at the sound
cover for the oil drain hose.
Summary of Contents for Panda 14.000 NE PVK-U
Page 1: ...Generator type Panda 14 000 NE PVK U 400V 50 Hz 12kW Icemaster Fischer Panda...
Page 28: ...The Panda Generator Page 24 Panda 14 000 NE PVK U S00420 Chapter A The Panda Generator...
Page 62: ...Generator Failure Page 58 Panda 14 000 NE PVK U S00420 Chapter D Generator Failure...
Page 92: ...Appendix Page VIII Panda 14 000 NE PVK U S00420 Chapter F Appendix...
Page 94: ...Measurements Page X Panda 14 000 NE PVK U S00420 Chapter F Appendix F 7 Measurements...
Page 96: ...Wiring diagram control panel Page XII Panda 14 000 NE PVK U S00420 Chapter F Appendix...