Installation Instructions
Panda 14.000 NE PVK-U S00420 - Chapter E: Installation Instructions Page 61
E.1.4 Connection to 12V Starter Battery-Block
An own separate 12V starter battery must be installed for the generator.
The positive cable (+) of the battery is attached directly at the solenoid switch of the starter motor
(position 1). The negative cable (-) of the battery is attached underneath the starter motor at the
engine mount (position 2).
ATTENTION!
It must be guaranteed that first the cables are attached at the generator and then at the
battery. To avoid large voltage drops the battery should be installed as near as possible to
the generator. The positive terminal of the battery is attached at the red cable, the negative
pole at the blue cable.
1
2
1. Generator
2. Battery block 12V