DIESEL MOTOR FAILS TO START
Cause
Solution
Starter battery switched "OFF".
Check position of battery switch and switch "ON" (if
installed).
Starter battery voltage insufficient (battery too weak).
Inspect battery terminals and cables for a good electri-
cal connection (Inspect against corrosion, tattered
wires, etc.).
Starting current disrupted.
During the normal starting process, the battery voltage
drops to 11V with a fully charged battery. If the voltage
does not drop during starting, the electrical connection
is faulty. If the battery voltage drops lower than 11V,
then the battery has been discharged.
STARTER IS TURNING MOTOR, BUT FAILS TO START
Cause
Solution
Fuel inlet solenoid valve not opening.
Check wire connections and circuitry to solenoid valve.
(ref. DC wiring diagram: Relay K2, Fuse)
Fuel pump not working.
Check fuel-filter and pump: clean if necessary.
Lack of fuel.
Check fuel supply.
Glow-plugs not working correctly.
Check glow plugs and heating time.
Too much air in fuel lines.
Test fuel system for leakage. Bleed air from fuel
system (refer to section "Bleeding Air from Fuel
System").
Fuel-filter blocked.
Replace fuel filter.
Low compression pressure.
See Kubota motor-manual.
MOTOR DOES ACHIEVE ENOUGH SPEED DURING STARTING PROCESS
Cause
Solution
Starter battery voltage insufficient.
Check battery.
Damaged bearing(s) piston (seized).
Repairs need to be carried out by Kubota-Service.
(refer to Kubota motor-manual)
Cooling water in combustion chamber.
1. Turn generator "OFF" at control panel.
2. Remove the glow plug (see Kubota-manual).
3. Rotate the motor by hand carefully.
4. Check if there is water in the oil and change both oil
and filter if necessary.
5. Determine cause for excess water in the combustion
chamber. The excess water can be caused by a
defective air vent in the cooling water system, which
should be checked and cleaned, or replaced if
faulty.
Summary of Contents for Panda 14.000 NE PVK-U
Page 1: ...Generator type Panda 14 000 NE PVK U 400V 50 Hz 12kW Icemaster Fischer Panda...
Page 28: ...The Panda Generator Page 24 Panda 14 000 NE PVK U S00420 Chapter A The Panda Generator...
Page 62: ...Generator Failure Page 58 Panda 14 000 NE PVK U S00420 Chapter D Generator Failure...
Page 92: ...Appendix Page VIII Panda 14 000 NE PVK U S00420 Chapter F Appendix...
Page 94: ...Measurements Page X Panda 14 000 NE PVK U S00420 Chapter F Appendix F 7 Measurements...
Page 96: ...Wiring diagram control panel Page XII Panda 14 000 NE PVK U S00420 Chapter F Appendix...