5.9.3.6 Installation location for radiator in a tunnel
A tunnel installation is implemented if the set-up location is separated from the vehicle cab by constructive
measures.
Please note:
• The total of the air intakes must be at least equal to the radiator width (
• The total of the cross-sections of the air ducts incl. lateral air intake must be at least equal to the radiator width
• The distance between generator and radiator must equal at least 1/2 the radiator width
• Lateral air supply between generator and radiator can be designed on the side, above, or below
Fig. 5.9.3.6-1: Incorrect installation in a tunnel
Incorrect installation in a tunnel
• Air intake too narrow
• Generator air intake too close to the wall
• Hot air can be taken in next to the radiator
• Exhaust gas line not insulated, heats up combustion air
Fig. 5.9.3-2: Correct installation in a tunnel
Correct installation in a tunnel
• Air intake (C) is min. radiator size (B) (safety grating and
decorative grille must be taken into account)
• Total of air intakes (A) equals min. the radiator size (B)
• Uninhibited air intake for generator
• Exhaust flow direction of radiator is shielded and air exhaust
enlarged (safety grating and decorative grille were taken
into account)
• Exhaust line insulated
Summary of Contents for 10000x
Page 10: ...Seite Page 10 Kapitel Chapter 2 10 6 16 Leere Seite Intentionally blank...
Page 96: ...Installation Instructions Seite Page 96 Kaptitel Chapter 5 Installation Instructions 10 6 16...
Page 148: ...Seite Page 148 Kapitel Chapter 9 Appendix 10 6 16 Leere Seite Intentionally blank Appendix...
Page 149: ...Panda_xControl_eng R01 5 10 6 16 Panda xControl Manual...
Page 189: ...Panda xControl 10 6 16 Kapitel Chapter 11 Panda xControl Seite Page 189...