5.21 Technical Data
Characteristics
closed current (electronics off)
0,5 mA
closed current (electronics on)
10 - 15 mA
Benchmark figure of the temperature control:
fan start-up
60 °C - 80 °C
max. number of revolution
65 °C - 100 °C
tolerance of the temperatures
± 5 %
Maximum ratings
maximum ambient temperature (for operation)
50 °C
Maximum ratings: Battery operation 12 V
nominal load operating voltage (continuity)
11 VDC - 14.4 VDC
load operating voltage (15min)
- 16.0 VDC
maximum idle speed operating voltage (3 sec)
17 VDC
nominal load current (continuity)
40 A
maximum load current (3 sec)
44 A
nominal voltage fan
12 VDC
Maximum ratings: Battery operation 24 V
nominal load operating voltage (continuity)
18 VDC - 28.0 VDC
load operating voltage (15min)
- 28.8 VDC
maximum load operating voltage (3 sec)
30 VDC
idle speed voltage (continuity)
34 VDC
maximum idle speed operating voltage (3 sec)
36 A
nominal load current (continuity)
20 A
maximum load current (3 sec)
22 A
nominal voltage fan
24 VDC
Maximum ratings: Transformer operation 12 V
sieving in the power supply
10000 µF 63 V (depending on the load current)
data for secondary winding after rectification/sieving
nominal load operating voltage (continuity)
11 VDC - 14.4 VDC
load operating voltage (15min)
- 16.0 VDC
maximum load operating voltage (3 sec)
17 VDC
idle speed operating voltage (continuity)
28 VDC
maximum idle speed operating voltage (3 sec)
30 VDC
nominal load current (continuity)
40 A
maximum load current (3 sec)
44 A
nominal voltage fan
12 VDC
Maximum ratings: Transformer operation 24 V
sieving in the power supply
10000 µF 63 V (depending on the load current)
data for secondary winding after rectification/sieving
full load operating voltage (15min)
18 VDC - 28.0 VDC
load operating voltage (15min)
- 28.8 VDC
maximum full load operating voltage (3 sec)
30.0 VDC
maximum partial load operating voltage
36.0 VDC
idle speed operating voltage (continuity)
39.0 VDC
maximum idle speed operating voltage (3 sec)
40.0 VDC
maximum input peak voltage
44.0 VDC *1)
maximum output peak voltage
44.0 VDC *1)
nominal load current (continuity)
24 A
Summary of Contents for 10000x
Page 10: ...Seite Page 10 Kapitel Chapter 2 10 6 16 Leere Seite Intentionally blank...
Page 96: ...Installation Instructions Seite Page 96 Kaptitel Chapter 5 Installation Instructions 10 6 16...
Page 148: ...Seite Page 148 Kapitel Chapter 9 Appendix 10 6 16 Leere Seite Intentionally blank Appendix...
Page 149: ...Panda_xControl_eng R01 5 10 6 16 Panda xControl Manual...
Page 189: ...Panda xControl 10 6 16 Kapitel Chapter 11 Panda xControl Seite Page 189...