Maintenance Instructions
Seite/Page 108 - Kaptitel/Chapter 7: Maintenance Instructions
10.6.16
Fig. 7.8-2: Oil dipstick
Oil dipstick EA 300 Engine
The oil-level is to be checked by means of the oil dipstick.
The prescribed filling level must not cross the „Max“-mark.
We recommend an oil-level of 2/3.
Sample picture
Oil should be refilled, if the oil-level is under 1/3 between the minimum and the maximum mark.
Fischer Panda recommends an oil-level of 2/3 between the minimum and the maximum mark.
If the oil-level is under the MIN-mark, check how many operating hours went by since the last oil change, by means
of your service manual or an existing oil change tag. - with operating hours between 50 and 150 hours it is only
necessary to refill oil. See „Refilling oil“ on page 2.
• with 150 operating hours or more the oil should be changed (See your generators’ service table)
• if the oil-level is under the minimum mark by less than 50h, there might be a technical problem! In that case, we
recommend going to a shop or a Fischer Panda service point.
• if the oil is cloudy or even „creamy“, coolant might have mixed with the oil. See a garage or a Fischer Panda service
point immediately.
7.8.1 Refilling oil
You require:
Engine oil
1. Check oil-level as described under section 7.8, “Checking oil-level,” on page 107.
2. Oil dipstick is pulled out of the check rail.
3. Open the oil filler cap.
4. Fill in oil (approx. 1/2 litre) and wait for about 2 min. so this it can flow into the oil pan.
5. Wipe off the oil dipstick and put it into the check rail.
6. Pull the oil dipstick out of the check rail and check the oil-level. See section 7.8, “Checking oil-level,” on
If oil-level is still too low (under 2/3): repeat steps 4-6.
7.8.2 After the oil level check and refilling the oil
• Put the oil dipstick back into the check rail.
• Close the oil filling cap.
• Remove potential oil stains and splashes from the generator and surroundings.
• Close the generator casing.
• Remove lock against accidental generator start.
Oil Max.
Oil Min.
2/3 Suggestion
Summary of Contents for 10000x
Page 10: ...Seite Page 10 Kapitel Chapter 2 10 6 16 Leere Seite Intentionally blank...
Page 96: ...Installation Instructions Seite Page 96 Kaptitel Chapter 5 Installation Instructions 10 6 16...
Page 148: ...Seite Page 148 Kapitel Chapter 9 Appendix 10 6 16 Leere Seite Intentionally blank Appendix...
Page 149: ...Panda_xControl_eng R01 5 10 6 16 Panda xControl Manual...
Page 189: ...Panda xControl 10 6 16 Kapitel Chapter 11 Panda xControl Seite Page 189...